China ADS-6000B Arteriosclerosis Detector: Suppliers of Advanced Artery Stiffness and Occlusion Testing Factory

The ADS-6000B Arteriosclerosis Detector is a cutting-edge device manufactured in China, boasting complete independent intellectual property rights. This advanced instrument is designed for assessing the degree of artery stiffness and occlusion, making it an essential tool for cardiovascular health evaluation. Utilizing synchronous pressurization, the ADS-6000B non-invasively measures blood pressure in the limbs while simultaneously recording and analyzing arterial pulse waveforms in real time, Employing sophisticated waveform analysis technology, this device extracts vital information representing vascular elasticity and calculates several key indices, including the Ankle-Brachial Index (ABI) and Brachial-Ankle Pulse Wave Velocity (baPWV). By leveraging extensive database data, it automatically analyzes and provides a comprehensive evaluation of the cardiovascular system's health status, as well as the level of arterial occlusion in the lower limbs, As a leading supplier in medical technology, our China-based factory is committed to delivering innovative solutions for the early diagnosis of arteriosclerosis and the proactive screening of cardiovascular and cerebrovascular diseases. The ADS-6000B serves as a reliable and objective reference for healthcare professionals, ensuring better patient outcomes

    Product Video

    Scope of Application

    🏥

    Suitable for cardiovascular and cerebrovascular medicine, geriatrics, physical examination centers, etc., and used to detect and evaluate lower limb vascular occlusion and vascular elasticity of subjects.

    Technical Parameter

    • ⚙️ Blood pressure measurement method: Blood pressure measurement using the oscillography; Measurement location: limbs (ankles, brachial arms).
    • ⚙️ Pressurization method: Synchronized pressurization of limbs.
    • ⚙️ Blood pressure module sensor accuracy: Measurement range ±3 mmHg under normal working environment.
    • ⚙️ Number of blood pressure modules: 4 (independent working blood pressure pump).
    • ⚙️ Measurement accuracy: < ±0.4 kPa (±3 mmHg).
    • ⚙️ Repeatability: ≤ 0.533 kPa (4 mmHg).
    • ⚙️ Blood pressure measurement range: 0–260 mmHg.
    • ⚙️ Pulse rate measurement range: 40–199 BPM.
    • ⚙️ Number of blood pressure cuff uses: 8,000 inflation and deflation cycles.
    • ⚙️ Applicable population: Up to the age of 100.
    • ⚙️ Database: A global racial database able to measure populations up to the age of 100.
    • ⚙️ Product dimensions: 37 cm × 40 cm × 10 cm; Product weight: 6.1 kg.
    • ⚙️ Main measurement parameters: baPWV (pulse wave velocity), ABI (ankle/brachial index), BAI (brachial ankle index), HR (heart rate), PVR (pulse volume recording).
    ADS-6000B Product Image 1
    ADS-6000B Product Image 2

    Frequently Asked Questions (FAQ)

    Q What clinical departments is this device suitable for?
    A This device is suitable for cardiovascular and cerebrovascular medicine, geriatrics, and physical examination centers. It is designed to detect and evaluate lower limb vascular occlusion and vascular elasticity in patients.
    Q What is the blood pressure measurement accuracy of this device?
    A The measurement accuracy is less than ±0.4 kPa (±3 mmHg), with a repeatability of ≤ 0.533 kPa (4 mmHg) under normal working conditions, ensuring highly reliable clinical readings.
    Q What key vascular parameters can the device measure?
    A The device measures baPWV (pulse wave velocity), ABI (ankle/brachial index), BAI (brachial ankle index), HR (heart rate), and PVR (pulse volume recording), providing a comprehensive vascular health assessment.
    Q How many blood pressure modules does the device have and how do they work?
    A The device is equipped with 4 independent blood pressure modules, each with its own dedicated pump. They support synchronized pressurization of all four limbs simultaneously, enabling efficient and consistent bilateral measurements.
    Q Is this device suitable for elderly patients?
    A Yes. The device supports measurement for populations up to 100 years of age and includes a global racial database, making it well-suited for geriatric departments and comprehensive physical examination programs.
    Q What is the durability of the blood pressure cuffs and what are the device dimensions?
    A Each blood pressure cuff is rated for 8,000 inflation and deflation cycles, ensuring long-term reliability. The device measures 37 cm × 40 cm × 10 cm and weighs 6.1 kg, making it compact and easy to place in clinical settings.