China ADS-6000A Arteriosclerosis Detector from Reliable Suppliers and Factory for Early Cardiovascular Health Screening
Product Description
🩺
ADS-6000A Arteriosclerosis Detector is an arterial stiffness and obstruction degree detector with complete independent intellectual property rights. The instrument uses synchronous compression to measure the blood pressure of the limbs noninvasively, simultaneously records and analyzes the pulse wave shape of the limbs, uses waveform analysis technology to extract the characteristic information that characterizes the blood vessel elasticity, calculates a number of indexes including ankle brachial index (ABI), brachial ankle artery pulse wave velocity (baPWV), and performs automatic analysis and comprehensive evaluation through the database data, to evaluate the health status of cardiovascular system and the degree of lower extremity artery obstruction, and provide comprehensive objective basis for early diagnosis of arteriosclerosis and early screening of cardiovascular and cerebrovascular diseases.
The most common causes of arteriosclerosis are hyperlipidemia, hypertension, diabetes, and the patient's own lifestyle. Relevant data show that the intake of greasy food and high-cholesterol food directly leads to hypercholesterolemia, and hypercholesterolemia is just one of the risk factors for atherosclerosis and cardiovascular disease.
For most patients with arteriosclerosis, early detection, early detection and reasonable intervention can effectively reduce the morbidity, disability rate and mortality of cardiovascular and cerebrovascular diseases.
Technical Features
1
Accurately Assess the Elasticity of the Great Arteries and the Degree of Lower Extremity Artery Obstruction
The ankle-brachial index measured by synchronous compression of all limbs reduces the influence of blood pressure variability, and the results are more accurate. baPWV + ABI measurement is more reliable in assessing large artery elasticity.
2
Simple, Fast, Non-Invasive Measurement Method
The use of high sensitivity pulse wave sensor non-invasive inspection will not bring any physical harm to the user. The instrument is simple to operate, the detection time is short, and the index measurement is completed quickly.
3
Network Function Supports Online Transmission and Remote Management
The network function can easily support online transmission and remote management of data.
4
Scientific Theoretical Basis and Accurate Test Data
Independent intellectual property rights, years of medical data accumulation, and passed clinical verification.
5
ABI Detected by Synchronous Compression of the Limbs
Due to the constant fluctuation of blood pressure, only ABI values measured by simultaneous compression of the extremities are more meaningful. The 2006 ACC/AHA guidelines for the management of peripheral artery disease recommend the use of simultaneous measurement of blood pressure on all limbs to obtain ABI values.
6
Risk Assessment of Cardiovascular Disease
The unique cardiovascular disease risk assessment system objectively assesses the 10-year risk of ischemic cardiovascular disease.
7
Network Interaction and Data Upload Function
The data can be batchly imported from the remote server, and the test data can be uploaded to the remote server at any time, and can be integrated with the health management system as needed.
8
Accurate Blood Pressure Measurement
The quality and performance of the internationally renowned blood pressure monitoring module are more reliable and the measurement results are more accurate.
Technical Parameters
- Blood pressure of the extremities measured synchronously by the oscillometric method.
- Measurement site: Limbs — upper arm, lower limb ankle.
- Arm circumference measurement range: 20–38 cm.
- Width range of lower limb measurement: 16 cm–33 cm.
- Rated power: 115 VA; Voltage: 220 V.
-
Performance requirements of blood pressure measurement:
Measurement range: 0 kPa ~ 34.7 kPa (0 mmHg ~ 260 mmHg);
Measurement accuracy: ±0.4 kPa (±3 mmHg);
Repeatability: measured under static continuous low pressure, the difference between the repeated measured readings at each point within the scale range is not greater than 0.533 kPa (4 mmHg). - 12.1-inch HD LCD screen, branded industrial control computer system.
- Measurement parameters: baPWV (brachial-ankle pulse wave velocity), ABI (ankle brachial index), BAI (brachial-ankle index), HR (heart rhythm), PVR (pulse volume recording), systolic blood pressure SBP (limbs), diastolic blood pressure DBP (limbs), mean blood pressure MAP (limbs), pulse pressure PP (limbs).
- Portable structural design, easy to move.
- Equipped with lithium battery, capacity of 5200 mAh.
- Lithium battery working time: up to 3 hours.
Frequently Asked Questions
Q
What is the ADS-6000A Arteriosclerosis Detector used for?
The ADS-6000A is used to assess arterial stiffness and the degree of lower extremity artery obstruction. It measures key indexes such as ABI (Ankle-Brachial Index) and baPWV (Brachial-Ankle Pulse Wave Velocity) to evaluate cardiovascular health and aid in the early screening and diagnosis of arteriosclerosis and cardiovascular/cerebrovascular diseases.
Q
Is the ADS-6000A measurement method safe and non-invasive?
Yes. The ADS-6000A uses high-sensitivity pulse wave sensors for non-invasive inspection. The measurement process will not cause any physical harm to the patient. It is simple to operate, with a short detection time, making it suitable for routine clinical use.
Q
Why is simultaneous limb compression important for ABI measurement?
Blood pressure fluctuates constantly, so measuring ABI using simultaneous compression of all four extremities produces more accurate and clinically meaningful results. This approach is recommended by the 2006 ACC/AHA guidelines for management of peripheral artery disease, which endorse simultaneous blood pressure measurement on all limbs to obtain reliable ABI values.
Q
What are the main risk factors for arteriosclerosis that this device helps address?
The most common risk factors for arteriosclerosis include hyperlipidemia, hypertension, diabetes, and lifestyle habits such as a diet high in greasy or high-cholesterol foods. The ADS-6000A enables early detection of arterial changes associated with these risk factors, supporting timely intervention and reducing the rates of morbidity and mortality from cardiovascular and cerebrovascular diseases.
Q
Does the ADS-6000A support remote data management and network integration?
Yes. The ADS-6000A is equipped with a network interaction and data upload function. Test data can be batch-imported from or uploaded to a remote server at any time. It can also be integrated with health management systems as needed, making it suitable for modern clinical and telehealth environments.
Q
What is the battery life and portability of the ADS-6000A?
The ADS-6000A features a portable structural design that makes it easy to move between rooms or facilities. It is equipped with a lithium battery with a capacity of 5200 mAh, providing up to 3 hours of continuous working time on a single charge — ideal for mobile clinical use.