Advanced Pulmonary Function Detector LUD-V2 - Reliable Respiratory Health Testing by China Suppliers and Factory
Product Video
Product Parameters
- 1. Measurement method: differential pressure flow test method
- 2. Sensor: High precision double differential pressure flow sensor
- 3. Flow measurement range: 0 L/s ~ ±14 L/s
- 4. Flow measurement error: The maximum allowable flow error in the measurement range should be: ±10 L/min (±0.17 L/s) or ±5% of the reading
- 5. Volume measurement range: 0–8 L | Volume measurement error: ±3% or ±0.050 L, whichever is the maximum
- 6. Airflow resistance: The airflow resistance within the test range should not exceed 0.35 KPa/(L/s)
- 7. Frequency response: no more than 0.25 L/s or 12%
- 8. Linearity: the difference of the average error of two adjacent test flows does not exceed 5% of the two test flows, and the test flow change does not exceed 0.17 L/S or 5% of the reading
- 9. Pulmonary function measurement: forced vital capacity (FVC), slow vital capacity (SVC), and voluntary ventilation (MVV) can be measured
- 10. Lung function measurements were guided by animation
- 11. Measurement parameters: FVC, FEV0.5, FEV1, FEV3, FEV1/FVC, PEF, MEF75, MEF50, MEF25, MMF, OI, FIVC, PIF, FIV1; VC, TV, ERV, IRV, IC, VC/HT; MVV, RR, MVV/BSA, TV, BSA
- 12. Volume-flow velocity curve and time-volume curve were generated according to the pulmonary function measurement results
- 13. Unique filter and mouth design — more tightness, prevent air leakage during measurement
- 14. It has the function of COPD assessment and ventilation defect assessment
- 15. System software functions: instrument zero and calibration function, doctor management system, history review system, medical record review function, user file management function
- 16. Display: ≥14.1 inch, high-definition color display
- 17. Built-in industrial control host structure, more stable performance
- 18. Logitech wireless keyboard and mouse operation, more convenient to use
- 19. Portable horizontal structure, exquisite and beautiful
- 20. Service life: 8 years
- 21. Operating system: WIN7 32 bit / 64 bit, WIN10 64 bit compatible
- 22. Power input: Voltage AC220V, Current 0.75A, Power ≤60VA
- 23. Dimensions: Depth 226mm × Width 400mm × Height 353mm | Weight: ≤8 kg
After-Sales Service
🛡️
1-Year Warranty
We provide a full one-year warranty on all products, ensuring your investment is protected.
🔧
Lifetime Maintenance
Permanent maintenance service beyond the warranty period — only materials and maintenance fees apply, no labor charges.
⚡
2h Response / 48h Resolution
Our team provides a 2-hour immediate response and commits to resolving faults within 48 hours.
Frequently Asked Questions
What pulmonary function tests can this spirometer perform?
This device supports Forced Vital Capacity (FVC), Slow Vital Capacity (SVC), and Maximum Voluntary Ventilation (MVV) measurements. It also generates volume-flow velocity curves and time-volume curves automatically based on test results.
What is the flow measurement accuracy of this device?
The maximum allowable flow measurement error is ±10 L/min (±0.17 L/s) or ±5% of the reading, whichever is greater. The volume measurement error is ±3% or ±0.050 L, ensuring high clinical precision.
Is this spirometer compatible with modern operating systems?
Yes. The device is fully compatible with Windows 7 (32-bit and 64-bit) and Windows 10 (64-bit), making it suitable for a wide range of clinical IT environments.
Does the device support COPD assessment?
Yes. The spirometer includes built-in COPD assessment and ventilation defect assessment functions, providing clinicians with comprehensive diagnostic support directly from the device.
What is the warranty and after-sales support policy?
The device comes with a 1-year warranty. After the warranty period, lifetime maintenance service is available — only material and maintenance costs are charged, with no labor fees. The support team guarantees a 2-hour response and fault resolution within 48 hours.
How is hygiene maintained between patients during testing?
The device features a unique filter and mouthpiece design that ensures a tighter seal and prevents air leakage during measurement. The disposable filter design helps maintain hygiene standards between individual patient tests.